|
|
|
|
|
|
|
|
A2108
Fully Auto UV Tape Curing System |
|
|
A2112 Fully Auto UV Tape Curing System |
|
|
|
|
|
|
|
Automatic metal film frame cassette loader system |
|
Automatic pick-up arm mechanism, to pick the work piece from the metal film frame
cassette into the UV irradiation chamber |
|
Automatic detection of work piece present inside the UV irradiation chamber |
|
Automatic triggering the UV irradiation spiral lamp (ON) to cure the work piece, once
the UV irradiation chamber detected work piece present |
|
Automatic trigger (OFF) the UV irradiation spiral lamp, once the work piece being
UV cure accordingly to the preset programming cure time set |
|
Automatic pick-up arm, unload the work piece from the UV irradiation chamber into
the metal frame cassette loader system |
|
Built in with an UV irradiation curing indicator |
|
Built in with a preprogramming memory, for 5,6 inches wafer curing timer |
|
Built in with a preprogramming memory, for 8 inches wafer curing timer |
|
Built in with a preprogramming memory, for 6 inches metal film frame curing timer |
|
Built in with a preprogramming memory, for 8 inches metal film frame curing timer |
|
Built in with a SELF DIAGNOSTIC error code display |
|
Built in with an ELECTRONIC TOUCH SCREEN |
|
|
(Subjected to change without prior notice) |
|
|
High Speed Flash UV Irradiation curing on UV tape. |
|
|
No Nitrogen gas required |
|
|
No clean gas filter required |
|
|
Longer life span on spiral lamp |
|
|
Higher throughput |
|
|
Capable of UV irradiation for 6 inches wafer |
|
|
Capable of UV irradiation for 8 inches wafer |
|
|
Capable of UV irradiation for 6 inches metal film frame |
|
|
Capable of UV irradiation for 8 inches metal film frame |
|
|
|
|
Power Supply |
: 220 - 240 Vac, Single Phase |
|
|
Ampere |
:15Amp |
|
|
Air Supply |
: 70 to 80 PSI |
|
|
Machine Weight |
: 400kg Est |
|
|
Dimension |
: 825 (L) x 975 (w) x 1150 (H) mm |
|
|
|
|
|
|
|
|
|
|
Automatic metal film frame cassette loader system |
|
Automatic pick-up arm mechanism, to pick the work piece from the metal film frame
cassette into the UV irradiation chamber |
|
Automatic detection of work piece present inside the UV irradiation chamber |
|
Automatic triggering the UV irradiation spiral lamp (ON) to cure the work piece, once
the UV irradiation chamber detected work piece present |
|
Automatic trigger (OFF) the UV irradiation spiral lamp, once the work piece being
UV cure accordingly to the preset programming cure time set |
|
Automatic pick-up arm, unload the work piece from the UV irradiation chamber into
the metal frame cassette loader system |
|
Built in with an UV irradiation curing indicator |
|
Built in with a preprogramming memory, for 8 &12 inches wafer curing timer |
|
Built in with a preprogramming memory, for 8 & 12 inches metal film frame curing timer |
|
Built in with a SELF DIAGNOSTIC error code display |
|
Built in with an ELECTRONIC TOUCH SCREEN |
|
|
(Subjected to change without prior notice) |
|
|
High Speed Flash UV Irradiation curing on UV tape. |
|
|
No Nitrogen gas required |
|
|
No clean gas filter required |
|
|
Longer life span on spiral lamp |
|
|
Higher throughput |
|
|
Capable of UV irradiation for 8 inches wafer |
|
|
Capable of UV irradiation for 12 inches wafer |
|
|
Capable of UV irradiation for 8 inches metal film frame |
|
|
Capable of UV irradiation for 12 inches metal film frame |
|
|
|
|
Power Supply |
: 220 - 240 Vac, Single Phase |
|
|
Ampere |
:15Amp |
|
|
Air Supply |
: 70 to 80 PSI |
|
|
Machine Weight |
: 500kg Est |
|
|
Dimension |
: 1070 (L) x 1080 (w) x 1150 (H) mm |
|
|
|
|